TRMF2 125A 3 Poles, Adjustable Comply IEC60947-2, Moulded Case Circuit Breaker
TRMF2 125A 3 Poles, Adjustable Comply IEC60947-2, Moulded Case Circuit Breaker
TRMF2 125A 3 Poles, Adjustable Comply IEC60947-2, Moulded Case Circuit Breaker
TRMF2 125A 3 Poles, Adjustable Comply IEC60947-2, Moulded Case Circuit Breaker
TRMF2 125A 3 Poles, Adjustable Comply IEC60947-2, Moulded Case Circuit Breaker
TRMF2 125A 3 Poles, Adjustable Comply IEC60947-2, Moulded Case Circuit Breaker

TRMF2 125A 3 Poles, Adjustable Comply IEC60947-2, Moulded Case Circuit Breaker

Member Details

ZHEJIANG QIANNA ELECTRIC CO.,LTD.

China

Manufacturer

  • Product Details
  • Company Profile

TRM series circuit breaker and auxiliaries comply with the following international standard: 1.IEC/EN 60947-1 Low-voltage switchgear and controlgear-part 1: General rules; 2.IEC/EN 60947-2 Low-voltage switchgear and controlgear-part 2: Circuit breakers; TRM series MCCB(Standard use environment for TRM series MCCB) 1. Ambient temperature: Within the range of -5oC--+55oC(However, when the temperature exceed 40oC,it should be considered to reduce the capacity to use); 2. Relative humidity: Within the range of 45%--85%; 3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered); 4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist; Classification: According to the poles: 1-pole, 2-poles, 3-poles, 4-poles According to the breaking capacity: S-type, H-type According to the rated current: Fix type, Adjustable type(08In-1.0In)

TRM series MCCB

Standard:
TRM series circuit breaker and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;

TRM series MCCB(Standard use environment for TRM series MCCB)
1. Ambient temperature: Within the range of -5oC--+55oC(However, when the temperature exceed 40oC,it should be considered to reduce the capacity to use);
2. Relative humidity: Within the range of 45%--85%;
3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered);
4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist;

Classification:
According to the poles:                                          1-pole, 2-poles, 3-poles, 4-poles
According to the breaking capacity:                       S-type, H-type
According to the rated current:                               Fix type, Adjustable type(08In-1.0In)


Technical data table: 

Ampere frame sizeTRMF2(125A)
Breaking capacity codeSH
Product code and poles1P2P3P4P1P2P3P4P
TRMF2-S1TRMF2-S2TRMF2-S3TRMF2-S4TRMF2-H1TRMF2-H2TRMF2-H3TRMF2-H4
Rated current, In(A)15, 20, 30, 40, 50, 60, 75, 80, 100, 125
Adjustable partRated current setting(0.8In-1.0In)χχ
Lockup device for operating handleχχ
Rated operational voltage, Ue(V), AC 50/60 Hz240/415
Rated insulation voltage, Ui(V)1000
Rated impulse withstand voltage, Uimp(kV)8
StandardConformity with IEC/EN 60947-2
Rated frequency(Hz)50/60
Rated short-circuit breaking capacity, Icu(kA)
AC240V18352550
415V-18-35
Ics=% * Icu50%100%50%100%
Mechanical life(circle)8500
Electrical life(circle)1500
Dimension:
Length*Width*Height
1-pole130*25*60
2-poles130*50*60
3-poles130*75*60
4-poles130*100*60


Built-in accessory:

TRE Built in accessory.png

Built-out accessory:
TRE Built out accessory.png

Company show: